10 Firmware update
This chapter provides you with information about the following topics:
iRMC S2/S3 firmware (overview)
Creating a memory stick for updating the firmware
Updating firmware images
Emergency flash
flash tools
I The current firmware versions are present on the ServerView Suite DVD 1
or can be downloaded manually from the Download section of the Fujitsu
Technology Solutions web server.
You can obtain the up-to-date version of the ServerView Suite DVD 1 at
two-monthly intervals.
I Besides the possibility of performing a firmware update, you can also
downgrade the firmware to the previous version.
I Before updating or downgrading the firmware, read the supplementary
documentation supplied with the new firmware carefully (in particular the
Readme files).
I Servers with iRMC S2 must be rebooted to activate the updated /
downgraded firmware. For servers with iRMC S3, no reboot is required
to activate the updated / downgraded firmware.
V CAUTION!
When updating / downgrading the firmware, note that the problem-free
operation of the firmware can only be guaranteed if the runtime firmware
and the SDR (Sensor Data Record, see page 355) both belong to the
same firmware release.