showlogs(8)
System Administration 391
Date: Log collection date and time (month day hour:minute:second
time-zone year)
The displayed time is the local time.
Code: Error code
Data is displayed in 16-byte format.
Occurred: Date (Month Day Hour: Minute: Second TimeZone Year) when
an error occurred.
This date is displayed as the local time.
Status: Error status
Either of the following is displayed:
Warning Partial degradation of the unit or warning
about the FRU
Alarm FRU failure or error
FRU: Suspected faulty unit
The suspected faulty units that are displayed and delimited by a
"," (comma) are the units most likely and second most likely to
be faulty. If there are three suspected faulty units, an "*"is
displayed next to the unit third most likely to be faulty. Display
of more than two suspected faulty units depends on whether
more than two suspected faulty units are detected.
Msg: Error description
Diagnostic
Code:
Detailed error code
The displayed code is a hexadecimal number.
UUID: Abbreviation for Universal Unique Identifier
This is a globally unique ID that is a 32-digit hexadecimal
number.
MSG-ID: Unique message ID
Diagnostic
Messages:
Detailed message
If the log has a detailed message, it is displayed.
Detail log: Scan log code
This code is displayed when the log includes a scan log.
Address: Displayed in hexadecimal notation.